← DWG SDK
API Reference

.NET API

Generated P/Invoke over the C ABI, with C# accessors over the FlatBuffers document. One managed call per C entry point; the same lifecycle and status codes.

Quick start

using Dwg;

using var doc = DwgDocument.Open("drawing.dwg");   // any version, R13-R2018
Console.WriteLine(doc.Version);                    // "AC1032"

// iterate model space in draw order, dispatch on kind
foreach (var e in doc.ModelSpace.Entities)
    switch (e.Kind)
    {
        case EntityKind.Line:  var l = e.AsLine();  Console.WriteLine($"{l.Start} → {l.End}"); break;
        case EntityKind.MText: Console.WriteLine(e.AsMText().Text); break;
        case EntityKind.Insert: Console.WriteLine(e.AsInsert().BlockName); break;
    }

// or by type across the whole drawing: doc.Lines, doc.Circles, doc.Inserts, doc.Texts
foreach (var layer in doc.Layers) Console.WriteLine(layer.Name);

doc.Header.InsUnits = 4;                            // edit — set units to mm
doc.Save("out.dwg");                               // serialize

DwgDocument is the API you use — open, read records, edit, and save, with no FlatBuffers or pointers. It wraps a generated P/Invoke layer over the C ABI (documented below for reference and for advanced use); the same 12 C entry points are there if you need them.

Entry points

dwg_last_error

const char *dwg_last_error(void)

Result of every entry point. `DWG_OK` is 0; everything else is a failure and leaves any out-parameter untouched. / enum dwg_status #if defined(__cplusplus) || __STDC_VERSION__ >= 202311L : int32_t #endif // defined(__cplusplus) || __STDC_VERSION__ >= 202311L { DWG_OK = 0, /** A file could not be read from disk. / DWG_ERR_IO = 1, /** The bytes are not a DWG this reader can parse. / DWG_ERR_PARSE = 2, /** A recognisable DWG whose version this build does not read. / DWG_ERR_UNSUPPORTED_VERSION = 3, /** The operation is not supported for this object's family — notably an edit to a family with no byte-exact writer. / DWG_ERR_UNSUPPORTED_FAMILY = 4, /** A null pointer, or a string that was not valid UTF-8. / DWG_ERR_INVALID_ARG = 5, /** A panic crossed into the boundary and was caught. A bug; please report. / DWG_ERR_INTERNAL = 6, /** A paid operation (write, apply) was attempted without a valid licence. Reading and compiling never return this. / DWG_ERR_UNLICENSED = 7, }; #ifndef __cplusplus #if __STDC_VERSION__ >= 202311L typedef enum dwg_status dwg_status; #else typedef int32_t dwg_status; #endif // __STDC_VERSION__ >= 202311L #endif // __cplusplus

dwg_set_license

dwg_status dwg_set_license(const char *key)

Install a licence key (the hex text issued to the customer).

dwg_doc_open

dwg_status dwg_doc_open(const uint8_t *bytes, size_t len, dwg_doc **out)

Parse a DWG from memory. Every version from R13 to R2018.

dwg_doc_open_path

dwg_status dwg_doc_open_path(const char *utf8_path, dwg_doc **out)

Parse a DWG from a UTF-8 path.

dwg_doc_close

void dwg_doc_close(dwg_doc *doc)

Close a document and free everything it owns.

dwg_doc_version

const char *dwg_doc_version(const dwg_doc *doc)

The document's version string, e.g. `"AC1032"`.

dwg_doc_object_count

size_t dwg_doc_object_count(const dwg_doc *doc)

How many objects the document holds — every entity and non-graphical object in `AcDb:AcDbObjects`, as the reader recovered them.

dwg_doc_compile

dwg_status dwg_doc_compile(const dwg_doc *doc, dwg_buffer **out)

Compile the document into the FlatBuffers form `the read schema (dwg_db.fbs)` describes.

dwg_doc_apply

dwg_status dwg_doc_apply(dwg_doc *doc, const uint8_t *script, size_t len, size_t *out_objects_changed)

Apply an edit script — a `the edit schema (dwg_edit.fbs)` buffer — to the document.

dwg_doc_write

dwg_status dwg_doc_write(const dwg_doc *doc, dwg_buffer **out)

Serialize the document back to DWG bytes.

dwg_buffer_data

const uint8_t *dwg_buffer_data(const dwg_buffer *buf)

Pointer to a buffer's bytes. `NULL` if `buf` is `NULL`.

dwg_buffer_len

size_t dwg_buffer_len(const dwg_buffer *buf)

A buffer's length in bytes. 0 if `buf` is `NULL`.

dwg_buffer_free

void dwg_buffer_free(dwg_buffer *buf)

Free a buffer. Passing `NULL` is a no-op.

The document API

DwgDocument hides the plumbing entirely.

using Dwg;

using var doc = DwgDocument.Open("drawing.dwg");

// ── read ──────────────────────────────────────────────
foreach (var layer in doc.Layers) Console.WriteLine(layer.Name);
foreach (var m in doc.MTexts)     Console.WriteLine(m.Text);

// ── header variables ──────────────────────────────────
int units = doc.Header.InsUnits;      // read
doc.Header.InsUnits = 4;              // set — millimetres
doc.Header.LineTypeScale = 2.0;
doc.Header.DimensionScale = 1.5;

// ── save ──────────────────────────────────────────────
doc.Save("out.dwg");                  // or: byte[] bytes = doc.Save();

Assigning a header property applies the change immediately and safely — an unsupported edit throws DwgException rather than corrupting the file. Records (Layers, MTexts, …) are read views over the drawing.

Under the hood

Advanced callers can reach the generated layers directly: P/Invoke (NativeMethods) over the C ABI, and FlatBuffers accessors over the document and edit schemas (dwg_db.fbs, dwg_edit.fbs, generate with flatc --csharp). DwgDocument is built on exactly these; you rarely need them.