C API
The C ABI — one small, stable boundary. Lifecycle, read (compile to a FlatBuffers document), and write (apply an edit script, then serialize). UTF-8 in and out, opaque handles, status codes.
Quick start
#include "dwg.h"
dwg_doc *doc = NULL;
if (dwg_doc_open_path("drawing.dwg", &doc) != DWG_OK) {
fprintf(stderr, "%s\n", dwg_last_error());
return 1;
}
dwg_buffer *document = NULL;
dwg_doc_compile(doc, &document); /* FlatBuffers document (schema/dwg_db.fbs) */
const uint8_t *data = dwg_buffer_data(document);
size_t len = dwg_buffer_len(document);
/* read `data`/`len` with the flatc-generated C++ accessors */
dwg_buffer_free(document);
dwg_doc_close(doc);Status codes
Every entry point returns dwg_status; DWG_OK is 0.
| Code | # | Meaning |
|---|---|---|
| DWG_OK | 0 | |
| DWG_ERR_IO | 1 | A file could not be read from disk. |
| DWG_ERR_PARSE | 2 | The bytes are not a DWG this reader can parse. |
| DWG_ERR_UNSUPPORTED_VERSION | 3 | A recognisable DWG whose version this build does not read. |
| DWG_ERR_UNSUPPORTED_FAMILY | 4 | The operation is not supported for this object's family — notably an edit to a family with no byte-exact writer. |
| DWG_ERR_INVALID_ARG | 5 | A null pointer, or a string that was not valid UTF-8. |
| DWG_ERR_INTERNAL | 6 | A panic crossed into the boundary and was caught. A bug; please report. |
| DWG_ERR_UNLICENSED | 7 | A paid operation (write, apply) was attempted without a valid licence. Reading and compiling never return this. |
Functions
dwg_last_error
const char *dwg_last_error(void)Result of every entry point. `DWG_OK` is 0; everything else is a failure and leaves any out-parameter untouched. / enum dwg_status #if defined(__cplusplus) || __STDC_VERSION__ >= 202311L : int32_t #endif // defined(__cplusplus) || __STDC_VERSION__ >= 202311L { DWG_OK = 0, /** A file could not be read from disk. / DWG_ERR_IO = 1, /** The bytes are not a DWG this reader can parse. / DWG_ERR_PARSE = 2, /** A recognisable DWG whose version this build does not read. / DWG_ERR_UNSUPPORTED_VERSION = 3, /** The operation is not supported for this object's family — notably an edit to a family with no byte-exact writer. / DWG_ERR_UNSUPPORTED_FAMILY = 4, /** A null pointer, or a string that was not valid UTF-8. / DWG_ERR_INVALID_ARG = 5, /** A panic crossed into the boundary and was caught. A bug; please report. / DWG_ERR_INTERNAL = 6, /** A paid operation (write, apply) was attempted without a valid licence. Reading and compiling never return this. / DWG_ERR_UNLICENSED = 7, }; #ifndef __cplusplus #if __STDC_VERSION__ >= 202311L typedef enum dwg_status dwg_status; #else typedef int32_t dwg_status; #endif // __STDC_VERSION__ >= 202311L #endif // __cplusplus
/** A block of bytes produced by the library. Freed with [`dwg_buffer_free`]. / typedef struct dwg_buffer dwg_buffer;
/** An open DWG document. Owns its decompressed sections and object inventory. / typedef struct dwg_doc dwg_doc;
#ifdef __cplusplus extern "C" { #endif // __cplusplus
/** Detail for the last failure on this thread, or `NULL` if the last call succeeded.
The pointer is owned by the library and stays valid until the next `dwg_*` call on this thread. Copy it if you need to keep it.
dwg_set_license
dwg_status dwg_set_license(const char *key)Install a licence key (the hex text issued to the customer).
This is the authenticate call the whole SDK requires: in a release build `dwg_doc_open`, `dwg_doc_compile`, `dwg_doc_write` and `dwg_doc_apply` all return `DWG_ERR_UNLICENSED` until a valid key is installed. Call it once at startup, before opening any document. Returns `DWG_ERR_UNLICENSED` if the key is malformed or its signature does not verify. In a debug build the gate is compiled out, so this is accepted but not consulted.
dwg_doc_open
dwg_status dwg_doc_open(const uint8_t *bytes, size_t len, dwg_doc **out)Parse a DWG from memory. Every version from R13 to R2018.
dwg_doc_open_path
dwg_status dwg_doc_open_path(const char *utf8_path, dwg_doc **out)Parse a DWG from a UTF-8 path.
dwg_doc_close
void dwg_doc_close(dwg_doc *doc)Close a document and free everything it owns.
Passing `NULL` is a no-op, so this is safe to call unconditionally in a cleanup path.
dwg_doc_version
const char *dwg_doc_version(const dwg_doc *doc)The document's version string, e.g. `"AC1032"`.
Borrowed from the document; valid until [`dwg_doc_close`]. `NULL` if `doc` is `NULL`.
dwg_doc_object_count
size_t dwg_doc_object_count(const dwg_doc *doc)How many objects the document holds — every entity and non-graphical object in `AcDb:AcDbObjects`, as the reader recovered them.
A cheap liveness check that needs no schema on the caller's side. Returns 0 for a `NULL` document.
dwg_doc_compile
dwg_status dwg_doc_compile(const dwg_doc *doc, dwg_buffer **out)Compile the document into the FlatBuffers form `the read schema (dwg_db.fbs)` describes.
The result is the read API: symbol tables, blocks with their entities in draw order, layouts, and one sorted index every cross-reference resolves through. Read it with the `flatc` accessors generated for your language.
The buffer is independent of the document — it stays valid after [`dwg_doc_close`], and it is what a caller would cache or mmap.
dwg_doc_apply
dwg_status dwg_doc_apply(dwg_doc *doc, const uint8_t *script, size_t len, size_t *out_objects_changed)Apply an edit script — a `the edit schema (dwg_edit.fbs)` buffer — to the document.
The authoring direction. A caller builds the script with the `flatc` accessors generated for their language, exactly as they read the compiled document with the read schema's. Nothing per-family crosses this boundary.
Objects the script does not name keep their original bytes, so a later [`dwg_doc_write`] preserves everything it was not asked to change. An operation on a family with no byte-exact writer is refused with `DWG_ERR_UNSUPPORTED_FAMILY` rather than re-encoded lossily.
The script is applied in order and is **not** transactional: if operation N fails, operations before it have already been applied. Check the status, and re-open the document if you need all-or-nothing.
`out_objects_changed` may be `NULL`. When given, it receives the number of objects whose bytes actually changed — lower than the operation count when a field was set to the value it already had.
dwg_doc_write
dwg_status dwg_doc_write(const dwg_doc *doc, dwg_buffer **out)Serialize the document back to DWG bytes.
Sections the caller has not changed are written back as they were read. That passthrough is the contract the corpus round-trip gate enforces: writing a document nobody edited reproduces the input byte for byte.
dwg_buffer_data
const uint8_t *dwg_buffer_data(const dwg_buffer *buf)Pointer to a buffer's bytes. `NULL` if `buf` is `NULL`.
Valid until [`dwg_buffer_free`]. Never `free()` it directly.
dwg_buffer_len
size_t dwg_buffer_len(const dwg_buffer *buf)A buffer's length in bytes. 0 if `buf` is `NULL`.
dwg_buffer_free
void dwg_buffer_free(dwg_buffer *buf)Free a buffer. Passing `NULL` is a no-op.
Schemas
The read model and the edit vocabulary are FlatBuffers schemas. Generate accessors for your language with flatc, then read the document / build edit scripts with them.
- dwg_db.fbs — the compiled document you read after
dwg_doc_compile. - dwg_edit.fbs — the edit script you pass to
dwg_doc_apply.
flatc --c dwg_edit.fbs # C builders for the edit script flatc --cpp dwg_db.fbs # C++ accessors for the document
Building an edit script
An edit script is a FlatBuffers EditScript: a list of operations. Two exist today — set a field on an object, and set a header/system variable (units, scales). Build it, then hand its bytes to dwg_doc_apply. C++ flatbuffers shown for readability:
#include "dwg_edit_generated.h"
using namespace dwg::edit;
flatbuffers::FlatBufferBuilder fbb;
// set INSUNITS = 4 (millimetres)
auto shv = CreateSetHeaderVar(fbb, fbb.CreateString("INSUNITS"),
Value_IntValue, CreateIntValue(fbb, 4).Union());
auto op = CreateOp(fbb, OpKind_SetHeaderVar, shv.Union());
fbb.Finish(CreateEditScript(fbb, fbb.CreateVector(
std::vector<flatbuffers::Offset<Op>>{op})));
size_t changed = 0;
dwg_doc_apply(doc, fbb.GetBufferPointer(), fbb.GetSize(), &changed);
dwg_doc_write(doc, &out);
For an object field, use CreateSetField with the object's handle, a field name (the names the document exposes, e.g. "Radius"), and a value. A family without a byte-exact writer is refused with DWG_ERR_UNSUPPORTED_FAMILY.